VOLKE · FJP

VOLKE FJP Integrated Flow, Pressure and Temperature Sensor

Manufacturer seriesFJP

An inline sensor combining flow, pressure and temperature measurement.

Measured variables
Flow, pressure and temperature 1
Flow measurement principle
Hall-sensed impeller 2
Nominal diameter options
DN6, DN8, DN10, DN15, DN20, DN25 3
Dn6 listed flow range
0.5 to 10 L/min 4
Request a Quote

VOLKE FJP Integrated Flow, Pressure and Temperature Sensor

VOLKE FJP Integrated Flow, Pressure and Temperature Sensor

Specifications

ParameterValue
FJP
Measured variablesFlow, pressure and temperature 1
Flow measurement principleHall-sensed impeller 2
Nominal diameter optionsDN6, DN8, DN10, DN15, DN20, DN25 3
Dn6 listed flow range0.5 to 10 L/min 4
Dn15 listed flow range5 to 50 L/min 5
Dn25 listed flow range12 to 120 L/min 6
Thread optionsG1/2 for DN6–DN15; G3/4 for DN20; G1 for DN25 7
Temperature measurement range0 to 100 degC 8
Supply voltage24 VDC 9
Process interface material304 stainless steel 10
Output choicesThree 4–20 mA channels or RS485 11
Specifications
Official product pageVOLKE FJP flow-temperature-pressure sensor, Shenzhen Volke Automation, opened 18 November 2026. Official product page: https://www.autovolke.com/index/marticle/index/aid/863.html
Official measured variables and principleFlow, pressure and temperature in one body; official impeller with Hall-effect switch plus separate pressure and temperature elements
Official flow rowsDN6 0.5–10 L/min G1/2"; DN8 1–15 L/min G1/2"; DN10 3–30 L/min G1/2"; DN15 5–50 L/min G1/2"; DN20 8–80 L/min G3/4"; DN25 12–120 L/min G1". Official accuracy class 3–5 is manufacturer wording, not a YOCOOLING guarantee.
Official pressure / temperaturePressure −0.1 to 1 MPa (official accuracy class 0.5); temperature 0 to 100 °C (official accuracy 1 °C)
Official electrical and materialsOutputs: three 4–20 mA channels or RS485; 24 VDC; official power consumption 3 W; housing aluminium oxide; process interface 304 SS; official IP67 (IP68 described as customizable)
Notes 11
  1. single integrated housing; exact output version to be selected
  2. supplier product description; fluid properties and calibration affect measurement
  3. series size options, not one universal body or flow range
  4. DN6 row; stated flow accuracy grade 3–5 is not a guarantee for all fluids
  5. DN15 row; measurement accuracy conditions require controlled manual
  6. DN25 row; do not apply to smaller fittings
  7. manufacturer table; verify each order-code and mating seal
  8. measurement span, not a combined process-temperature or coolant compatibility rating
  9. supplier webpage summary; wiring variant must be confirmed
  10. interface only, not a complete wetted-material statement
  11. supplier webpage lists options; verify exact version, protocol and pinout before specifying