Working, Proof & Burst Pressure

Learn the difference between operating pressure and pressure-test ratings.

On this page

Separate the pressure terms

Working pressure describes the allowed operating envelope for a specified component and conditions. Proof is a non-destructive test level and method. Burst describes failure testing. These values have different purposes and must not be substituted for each other.

State the test conditions

Define component or full-assembly scope, fluid or gas, temperature, hold time, ramp method, connected state and acceptance criterion. Identify normal, peak, transient and reverse pressure separately where relevant.

Check the complete assembly

The complete assembly includes hose, tube, fittings, seals and instruments. Do not claim the assembly inherits the strongest individual part rating; request the rating and verification of the proposed configuration.

Quote Request Checklist

  • Normal and peak operating pressure
  • Proof-test pressure and hold method
  • Burst requirement and safety boundary
  • Temperature, fluid, cycle state, and assembly configuration