Raychem · TT1000
Raychem TT1000 Modular Water-Sensing Cable
Manufacturer seriesTT1000
Official Raychem TraceTek TT1000 datasheet (RAYCHEMTraceTek-DS-H53870-TT1000-EN-2603), opened 18 November 2026, describes modular water-sensing cables with factory-installed plastic connectors that plug together. Official construction is two sensing wires, an alarm signal wire, and a continuity wire embedded in a fluoropolymer carrier rod. Official product characteristics include 0.24 in (6.0 mm) nominal cable diameter, high-visibility yellow color, and a maximum continuous operating temperature of 167°F (75°C). Official performance data on that sheet include a leak size to alarm of 2 in (50 mm) maximum at any point along the sensing cable, up to 5000 ft maximum system length, and a stated drying time of within 15 seconds after removal from standing water; those are manufacturer datasheet figures, not a YOCOOLING installation or performance guarantee. Official modular catalog lengths are listed from 1 m to 50 m, plus bulk cable TT1000-SC; those official catalog rows are not a YOCOOLING stock list, and a complete official catalog number is still required to enquire. The official nVent product URL opened today redirected to the Chemelex Raychem product page. Send the official catalog number, required length, and the alarm/locating module to be used. This page is not a stock, price, lead-time, approval or warranty statement. Official sources: https://cdn.chemelex.com/Product%20Documents/Data%20Sheets/RAYCHEMTraceTek-DS-H53870-TT1000-EN.pdf and https://www.chemelex.com/en-us/raychem/products/tt1000-water-sensing-cable-modular
- Cable diameter
- 6.0 mm nominal
- Maximum continuous operating temperature
- 75 °C (167 °F)
- Official cable diameter
- 0.24 in (6.0 mm) nominal
- Official maximum continuous operating temperature
- 167°F (75°C) (official datasheet)
Specifications
| Parameter | Value |
|---|---|
| TT1000 modular sensing cable | |
| Product identity | TT1000 modular water sensing cable with factory-installed plastic connectors |
| Detection method | Conductive-polymer cable detects water along its length when used with a compatible alarm and locating module |
| Application scope | Data-center subfloors, mechanical rooms, pipes and other flat-surface leak-detection areas |
| Cable construction | Two sensing wires, one alarm signal wire and one continuity wire embedded in a fluoropolymer carrier rod |
| Cable diameter | 6.0 mm nominal |
| Available modular lengths | 1, 3, 5, 7, 15, 30 and 50 m catalog versions with factory-installed connectors |
| Maximum continuous operating temperature | 75 °C (167 °F) |
| Specifications | |
| Official series document | Raychem TraceTek TT1000 datasheet RAYCHEMTraceTek-DS-H53870-TT1000-EN-2603, opened 18 November 2026 |
| Official construction | Two sensing wires, one alarm signal wire and one continuity wire embedded in a fluoropolymer carrier rod; factory-installed plastic connectors (official datasheet) |
| Official cable diameter | 0.24 in (6.0 mm) nominal |
| Official maximum continuous operating temperature | 167°F (75°C) (official datasheet) |
| Official performance notes (manufacturer) | Leak size to alarm: 2 in (50 mm) maximum at any point along the sensing cable; up to 5000 ft maximum system length; official drying-time statement: cable dries and resets within 15 seconds of removal from standing water. Manufacturer figures, not a YOCOOLING guarantee. |
| Official modular catalog lengths | Official table lists TT1000-1M/3FT-PC through TT1000-50M/165FT-PC, plus bulk TT1000-SC (connector kits required). Official rows are not a YOCOOLING stock list. |
| Official datasheet URL | https://cdn.chemelex.com/ProductDocuments/DataSheets/RAYCHEMTraceTek-DS-H53870-TT1000-EN.pdf |
| Official product page URL | https://www.chemelex.com/en-us/raychem/products/tt1000-water-sensing-cable-modular |