Component selection guide

Leak, Flow & Pressure Test Questions

What to include when requesting leak, flow or pressure-test information.

On this page

Make leakage measurable

Define test fluid, pressure, duration, component state, permitted leakage and measurement method. For quick disconnects, specify whether the limit applies connected, during actuation or disconnected.

Tie flow to its conditions

State flow rate and allowable pressure drop with fluid, concentration, temperature and the exact flow path. Record whether the result is for one component, a mated pair or an assembled branch.

Request test records

Ask which samples are tested, instrument calibration, inspection record, traceability and drawing revision. A supplier statement without method and conditions is not an acceptance test.

Quote Request Checklist

  • Test fluid and temperature
  • Connected or disconnected state
  • Flow range and allowable pressure drop
  • Leak limit, instrument accuracy, cycle count, and sample size

Related reading

If only some parts of a loop will be replaced after a leak, see What to send after a loop leak when only some liquid-cooling parts will be replaced.

Official-specification examples useful when you are naming a sensing cable, check valve or last-chance screen in a quote — not a stock list — include Raychem TraceTek TT1000, Lee 8 mm Insert Zero Leak Check Valve, and Lee 12 mm BR Series Safety Screen.

An official integrated flow-pressure-temperature sensor page can also be used as a specification example when the installed instrument type is not yet confirmed (not a stock statement): VOLKE FJP integrated flow, pressure and temperature sensor.